KD420 Modbus Sensor Interface

    KD420 Modbus Sensor Interface

    Manufacturer: KK Systems


    Price: $259.99

     

    • Description
    • Downloads

     The KD420 is a Modbus sensor interface which allows any 4-20mA or voltage output sensor to appear as a Modbus RTU Slave on an RS485 multidrop bus. The analog inputs are:

     
    •  Analog voltage -30V to +30V
    •  Analog current 4-20mA (a 20V sensor supply is provided)
    •  An external relay contact can be sensed
     
    The sensor value is presented in a set of Modbus registers, concurrently in several formats:
     
    40000: Current in 4-20mA range (logical value: 1=yes, 0=no)
    40001: Current - as a 16-bit unsigned integer in microamps (0 to 64000)
    40002: Current - as a 32-bit IEEE float. point value, big-endian, mA (2 registers)
    40004: Current - as above, little-endian (2 registers)
    40006: Current - as a null-terminated textual float +00.000, mA (8 registers)
    40020: Current - as above, E notation +0.000E+00 (11 registers)
    40101: Voltage - as a 16-bit signed integer in millivolts (-32000 to +32000)
    40102: Voltage - as a 32-bit IEEE float. point value, big-endian, V (2 registers)
    40104: Voltage - as above, little-endian (2 registers)
    40106: Voltage - as a null-terminated textual float +00.000, V (8 registers)
    40120: Voltage - as above, E notation +0.000E+00 (11 registers)
    The KD420 can also act as a Modbus RTU Master and write the data into a Modbus RTU Slave over 2-wire RS485, using a separate RS485 interface.
     
    The KD420 works straight out of the box but can be reconfigured using either a supplied Windows configuration program (via a suitable RS422/485 interface) or by writing values to special Modbus registers. Baud rates from 30 to 115200 baud are supported and up to 200 readings per second can be achieved.
     
    Accuracy is specified at 1% over the entire operating temperature range of -25C to +70C. Resolution is 0.03%. Industrial use is facilitated by configurable filtering over the 50Hz or 60Hz mains cycle period for maximum mains noise rejection.
     
    The KD420 is powered from 11 to 35V DC, or 24V DC if its 20V sensor power output is required. The Modbus comms interface, the analog sensor interface, and the power input are all mutually isolated and 100% tested at 1500V AC.
     
    The KD420 provides a simple and inexpensive means of interfacing a variety of sensors (for example PT100 temperature, flow or pressure sensors) to an existing SCADA or telemetry system.

    Customers who purchased this product, also purchased...



    Free UPS Ground Shipping On Orders Over $99

    Sign up for our newsletter containing updates and exclusive content!


    Customer Reviews

    Privacy Policy|Terms and Conditions|RoHs|Quality Statement|Returns|Sitemap

    © 2007- Saelig Company, Inc. All Rights Reserved.
    Other products, logos and company names mentioned herein, may be trademarks of their respective owners.
    eCommerce Shopping Cart Software by Miva Merchant