• Saelig 39 Years in business!
  • Your Technical Distributor
  • Saelig Scope Selection
  • Not Your Average Web Store
  • Saelig Values
  • Cambrionix
  • Siglent Spectrum Analyzers
  • siglent promotions
  • Rigol DG900 Pro
  • Disklabs
  • Windfreak
  • Ramsey
  • Rigol DG800 Pro
  • Siglent Products
  • PS4000A
  • Triarchy
  • KK Systems
  • MSR
  • PicoScope Dataloggers
  • Saelig Newsletter Signup
  • Choosing An Oscilloscope
  • Ramsey
  • Rigol DG800 Pro
  • Siglent Products
  • PS4000A
  • Triarchy
  • KK Systems
  • MSR
  • PicoScope Dataloggers
  • Saelig Newsletter Signup
  • Choosing An Oscilloscope
  • ABI Electronics
  • Rigol
  • PicoScope 2000
  • Pico Automotive
  • Siglent SSA3000X-R
  • Rigol
  • Aim-TTi
  • >
  • Sensepeek
  • YouTube Videos
  • Saelig Name Origins
  • PicoScope 6000E
  • ABI
  • Siglent
  • Rigol
  • Rigol
  • Disklabs
  • Siglent Portable Scopes
  • SpectraTronix
  • ChargeBox
  • Rigol MSO
  • MegiQ
  • Saelig-Kerr
  • JRE Test
  • GL Optic
  • SAF Tehnika
  • PREEN
  • Rigol Waveform Generators
  • PicoScope 6000E
  • Tekbox
  • Micsig
  • Lorlin
  • AIM TTi
  • ThinkRF
  • Amplicon
  • ed-k
  • Saelig Scope Selection
  • Rigol MSO5000
  • HT Instruments


Sciospec ISX-3 Impedance Analyzer

    Sciospec ISX-3 Impedance Analyzer

    Manufacturer: Sciospec Scientific Instruments


    From $8,500


    Frequency Range:
     
    10MHz 
    40MHz Add $4,641.00
    100MHz Add $9,945.00

    Integrated Multiplexer
    None 
    Second 4-electrode Setup Channel
     Add $663.00
    External 32-channel any-to-any multiplexer
     Add $4,199.10
    External 64-channel any-to-any multiplexer
     Add $6,200.00

    Options
     
    IoPort Add $1,270.75
     
    SyncPort Add $685.10


    Please request a quote for additional product options including:  


    • Additional Functionality (Medical Power Supply, Isolated IoPort, IoPort, Sync Port, Battery, Wifi)
    • Frontpanel Connectors (BNC-default, SMA, MCX, Banana Plug, DSUB, other)
    • Integrated Multiplexers  (32-Ch, 64-Ch, second 4-electrode setup channel)
    • Chip Adapters & External Muliplexers (32-Ch, 64-Ch, MEArack, ECISadapter)
    • Accessories (AC coupling interface, more listed below)
    • Cable Sets (BNC-Kelvin Clips, BNC-BNC, BNC-Banana Plug, BNC-MCX)

    Delivery 8-10 weeks

    • Description
    • Features
    • Specifications
    • Downloads

    The Sciospec Medical Research ISX-3 Impedance Analyzer, which is intended to facilitate the use of impedance spectroscopy in medical research applications. With Sciospec’s class-leading ISX-3 Impedance Analyzer as its basis, the Medical Research ISX-3 is equipped with enhanced electrical safety considerations in accordance with DIN EN 60601-1:2013, including medical grade isolation, enabling safe operation of the instrument in medical research settings. Isolation applies to both the power supply as well as the operator interfaces on the measurement ports (equivalent to "patient" interface connections). Sciospec’s IF frontend with 4-port BNC interface supports simple 2-point measurements, as well as 3- and 4-electrode configurations. With an available frequency range from 100mHz to 10MHz (extendable to 40 or 100MHz) the Medical Research ISX-3 Impedance Analyzer covers an impedance dynamic range measurement of 300dB (mOhm to TOhm) with a precision of 0.01%. 

    The Sciospec Medical Research ISX-3 Impedance Analyzer is designed to inject an electrical excitation stimulus (applied voltage or injected current) and then measure the response of the object being tested, both the voltage drop across the object and the current flow through the object, to derive the complex impedance value. The excitation stimulus is applied as a sinusoidal signal with varying frequency and/or amplitude. 

    The Medical Research ISX-3 Impedance Analyzer is not a medical product and as such its intended purpose does not include diagnosis and/or treatment of patients; but for purposes of biological research it includes added safety measures in accordance with DIN EN 60601-1:2013-12 "Medical electrical equipment – Part 1: General requirements for basic safety and essential performance". These measures assist research applications requiring exemptions for experiments on patients which require the prevention of contact between electrical circuitry and external equipment or humans, shielding of measurement front-end circuitry (noise reduction), and mechanical safety. The AC-coupled front-end consists of an external module for the measurements ports. This blocks DC currents and adds a high-pass filter to limit the signals to low frequency currents. These techniques effectively isolate the instrument galvanically from the measurement object or patient interface.

    Medical Research ISX-3 Impedance Analyzer is powered by an external isolated AC/DC converter which provides 12 V DC, with a software controllable electromechanical switch-off for DC input lines. Stand-alone battery operation is also possible. 




    Free UPS Ground Shipping On Orders Over $99

    Sign up for our newsletter containing updates and exclusive content!


    Customer Reviews

    Privacy Policy|Terms and Conditions|RoHs|Quality Statement|Returns|Sitemap

    © 2007- Saelig Company, Inc. All Rights Reserved.
    Other products, logos and company names mentioned herein, may be trademarks of their respective owners.
    eCommerce Shopping Cart Software by Miva Merchant